Titanium Strip Anode for Cathodic Stripping: Design and Application in PCB Plating
A titanium strip anode is a flat rectangular titanium plate used in a cathodic stripping cell, where plated metal is dissolved back off a workpiece. Specify a strip anode when your parts are large flat panels hung on a line, when you need uniform current distribution across a wide surface, and when the electrolyte is acidic or chloride-bearing. Unlike a rod anode, a strip presents a broad flat working face to the work. Unlike a basket anode filled with loose chips, it sheds no particles into the bath. For general orientation on titanium anode selection, see our titanium anode technical guide for industrial buyers.
What a Titanium Strip Anode Is and How It Differs from Other Anode Forms
A strip anode is a commercially pure titanium sheet, typically Grade 2, cut to a narrow ribbon with a defined width and length, supplied plain or with a mixed metal oxide (MMO) coating if the bath requires it. The defining feature is not the material but the geometry: a long, thin, flat anode that hangs vertically into the cell, parallel to the workpiece, fed by a contact at one end or along one long edge.
Strip versus rod anodes
A rod or bar anode is cylindrical. It presents a small discrete active surface, so the local current density is high and the solution near it runs hotter and more aggressive. Rod anodes also have a poor surface-area-to-volume ratio, so more metal must dissolve to deliver the same current. A strip uses the flat face of the plate, giving a much larger active surface in a compact footprint, so the same current is carried at lower local current density with better heat distribution.
Strip versus basket anodes
A basket anode is a titanium mesh basket loaded with soluble metal, typically copper or nickel chunks, that dissolves and replenishes metal ions into the bath. It is the standard choice when the bath must stay saturated with dissolved metal. The trade-off is that a mesh basket can shed fines, broken pieces, and coating debris, a real contamination risk in fine-pitch PCB work where one particle can ruin a trace. A solid titanium strip produces no loose particles. Our comparisons of basket anode mesh geometry and open area and titanium mesh basket anodes for plating will help you pin down the open-area and current-density trade-offs.
The cathodic stripping process it serves
Cathodic stripping, also called reverse electroplating, is the step in which a plated workpiece is reversed in polarity and its coating is dissolved back into solution. It recovers metal that plated onto racks, fixtures, and reject parts, and it is used in pattern-transfer operations where deposited copper on a carrier must be removed. The titanium strip must be electrically connected, inert enough to survive the bath, and geometrically matched to the work so current distributes evenly over the panel.
Technical Parameters and Comparison
The table below gives the working ranges we treat as standard for cathodic stripping and general electroplating cells.
| Parameter | Standard range | Notes for the buyer |
|---|---|---|
| Material | ASTM Grade 2 titanium, CP-Ti | Grade 1 when higher ductility for deep forming is needed |
| Coating | Bare titanium or MMO-coated | Bare for fluoride or strongly acidic baths that would dissolve the coating; MMO for higher current density or life |
| Strip thickness | 0.5 to 3.0 mm | 1.0-1.5 mm is usual; thicker for heavy racking |
| Strip width | 25 to 300 mm | Set by panel width and required total anode area |
| Strip length | 500 to 3000 mm | Must match cell immersion depth |
| Active surface area | 0.02 to 0.9 m² per strip | Both faces work; area = 2 × width × length |
| Operating current density | 0.5 to 3.0 A/dm² on the active face | Required total current divided by total installed anode area |
| Edge contact design | Bolted terminal tab, welded M8/M10 stud lug, or knurled clamp contact | Tab and lug types suit a bus bar; knurled clamp suits drop-in strip installations |
| Typical strip count per cell | 4 to 40 strips | Depends on cell width, panel size and target current; normally spaced evenly |
| Connection to bus bar | Copper or titanium lead with lug, or direct bolted contact | Lead length should allow the strip to be lifted out for cleaning |
Two checks matter more than buyers expect. First, immersion depth: only the submerged length carries meaningful current, and the portion above the liquid line is where crevice corrosion and salt deposits begin. Second, anode-to-work distance. Parallel strips spaced 150 to 250 mm from the panel give the most even distribution; crowding them together starves the panel centre.
Selection and Purchasing Advice
Fix these parameters before requesting a quotation, because each changes the geometry, the price, and the delivery date.
- Panel size and workpiece orientation. Strip width should match the vertical dimension of the work, not the horizontal. A strip wider than the panel gives poor edge-to-centre distribution; a much narrower strip requires more strips to carry the same current.
- Required total cell current. Divide by achievable current density to get total installed anode area, then convert area into strip count. Doing this in the wrong order is the most common reason a quotation arrives with twice the strip count the cell can accept.
- Strip dimension. Thickness, width, and length must be stated as cut dimensions. Below 0.8 mm is not recommended, because handling and the edge connection dominate the life.
- Edge contact method. Decide between a bolted terminal tab, a welded stud lug, and a knurled clamp contact before ordering. This determines the cell-side hardware and cannot be changed after delivery.
- Electrolyte compatibility. State the bath chemistry, temperature, and contaminants. Fluoride-bearing baths attack MMO coatings and require bare titanium. Chloride-rich baths at elevated temperature accelerate pitting, pushing you toward thicker material and a defined cleaning interval. For coating decisions, see our comparison of MMO versus platinum-coated titanium anodes.
- Service environment. Tell us whether the cell runs continuously or intermittently, whether the strips are lifted out regularly, and whether they are cleaned in place.
Send a drawing if you have one. A dimensioned sketch showing panel size, immersion depth, bus bar height, and strip spacing removes most of the back-and-forth that would delay the quotation.
Factory Capability
Boni Tech manufactures titanium strip anodes as a cut, formed, and finished component rather than as a sheet off the shelf. Raw grade 2 titanium sheet and plate are sourced against a mill certificate, then cut to the strip width and length you specify. Cutting runs on equipment that holds a consistent edge and flat profile across the full length, since a bowed or tapered strip will not hang parallel to the panel and produces uneven plating.
Edge connections are made in-house: a rolled or welded terminal tab, a stud lug for direct bus bar bolting, or a knurled contact band. Each is machined and deburred so the interface with the bus bar is flat and makes full contact without shimming. Weld operations run under controlled inert atmosphere so the titanium does not pick up oxidation or embrittlement at the joint, and the assembly is stress-relieved where welding was used.
Every strip is inspected for flatness, straightness, length and width against the drawing, and edge quality. Where MMO coating is specified, coating thickness and adhesion are verified across the working face, with attention to the transition zone near the edge connection where handling damage starts. Bare titanium parts are checked for surface contamination, pickling residue, and stray iron from shared tooling, an avoidable cause of localised attack in service. Dimensional reports and coating data can be issued with the shipment.
Lead time depends mainly on the coating route. Plain grade 2 strips cut to size are among the quickest items we produce. MMO-coated parts add a coating and firing cycle, and platinum-coated variants take longer still. The test data supporting these components is covered in our overview of performance evaluation of titanium anodes through physical testing methods.
Frequently Asked Questions
How many strip anodes does a typical PCB stripping cell need?
It depends on cell width, panel size, and required current. A common single-tank cell at moderate current uses 8 to 16 strips, while wide horizontal tanks with high throughput can take 30 or more. The calculation is based on total installed active area against target current density, so provide your cell dimensions and current requirement for an accurate count.
Should strip anodes be bare titanium or MMO coated for stripping baths?
It depends on the electrolyte. MMO coated strips suit most conventional acid sulfate and chloride plating baths because they carry higher current density and resist passivation. Bare grade 2 titanium is required where the bath contains fluoride or other species that attack the oxide layer. If the bath chemistry is not fully known, bare titanium is the safer starting point.
What is the effect of strip spacing on plating uniformity?
Spacing governs current distribution. Strips placed too far apart leave a weakly plated zone in the middle of the panel, while crowded strips create overlap and wasted anode surface. Space parallel strips evenly at 150 to 250 mm from the work and keep the same spacing across the full tank width.
How do I prevent titanium strips from becoming the weak link in the cell?
Use the thickness matched to your handling method, specify a connection design that allows the strip to be lifted out for cleaning, and set a cleaning interval for the submerged edge above the liquid line. Salt deposits at the liquid line are the usual starting point for pitting and are far easier to remove early than to ignore.
Can strip anodes be used as cathodes in a cathodic stripping cell?
In a cathodic stripping cell the workpiece is reversed and becomes the anode, so the titanium strip serves as the cathode and carries the workpiece plating back into solution. The strip must be connected as the cathode and sized so the required stripping current is spread over enough surface. Most buyers run one cell with both a stripping position and a plating position using the same strip hardware, so connection design matters as much as geometry.
Request a Quotation
To get an accurate quotation for titanium strip anodes for cathodic stripping, please send us the following:
- A drawing or dimensioned sketch showing strip length, width, and thickness, panel size, immersion depth, and bus bar or clamp position.
- Technical specifications including material grade, coating requirement (bare titanium, MMO, or platinum), surface treatment, and edge connection type.
- Process data covering the electrolyte chemistry, operating temperature, required cell current, target current density, and number of strips per cell.
- Quantity per size, and whether repeat orders are planned so we can reserve material and production capacity.
- Destination including country, city, and port or airport, plus any inspection or documentation requirements for the receiving plant.
Send the information to our engineering team and you will receive a dimensioned drawing for approval, a material specification, a lead time, and a firm price. If you are still comparing substrate options, our guide to titanium anodes for electroplating covers coating selection and service life in more detail.